Clinical Blood Pressure Monitor

Medix Automatic Digital Blood Pressure Monitor quickly and accurately measures your blood pressure with a push of a single button.

It comes with an easy-fit-all cuff for accurate and comfortable reading.

Certification

Categories: ,

Functions

 

LCD display signal

 

 

Specifications

Power supply Battery powered mode:
6VDC 4*AA batteries
AC adaptor powered mode:
6V — 1A
Display mode Digital  LCD  V.A.60*80mm
Measurement mode Oscillographic testing mode
Measurement range Rated cuff pressure:
0mmHg-300mmHg (0kPa-40kPa)
Measurement pressure:40mmHg-230mmHg
(5.3kPa-30.7kPa)
pulse value:(40-199)beat/minute
Accuracy Pressure:
5°C-40°C within±0.4kPa(3mmHg)
pulse value:±5%
Operation condition Temperature:5°C to 40°C Relative humidity ≤85%RH
Atmospheric pressure: 86kPa to 106kPa
Storage & transportation
condition
Temperature:-20°C to 60°C
Relative Humidity: 10%RH to 93%RH
Atmospheric Pressure: 50kPa to 106 kPa
Measurement perimeter
of the upper arm
About 22cm~32cm
Weight Approx.300g(Excluding the dry cells)
External dimensions Approx.102mm×143mm×73mm
Attachment 4*AA batteries, user manual
Mode of operation Continuous operation
Degree of protection Type BF applied part
Protection against
ingress of water
IP21

FAQs

How to set date and time?
Before using the blood pressure monitor for the first time, remember to set the date, time and measurement unit so that data’s can be stored accordingly to your memory.

  1. To set the time, press “SET” for 3 seconds to enter the “year” setting.
  2. Press “MEM” to navigate and “SET” to confirm.
  3. Continuously repeat the steps to set the month, day, hour and minutes.
  4. After which the device will automatically display “Done” and turn off.
How to read the measurement?
SYMBOL DESCRIPTION EXPLANATION
Systolic blood pressure High pressure measurement result
Diastolic blood pressure Low pressure measurement result
Pulse Pulse/minute
Deflating CUFF air is exhausting of deflating
Time (hour:minute) Current time
Memory Displays measurement values from the stored memory. For instructions, refer to the manual.
mmHg Measurement Unit of blood pressure
Low battery Batteries are low and need to be replaced
Arrhythmia Irregular heartbeat
Grade The grade of blood pressure
For instructions, refer to the manual.
What is the systolic pressure and diastolic pressure
  • When ventricles contract and pump blood out of the heart, blood pressure reaches its maximum value. The highest pressure is known as the “systolic pressure”.
  • When the heart relaxes between heartbeats, the lowest blood pressure is the “diastolic pressure”
How to recall records

Press the “MEM” button to recall records. Press “Mem” or “SET” button to navigate through the records. Kindly note that the device can only store up to 60 records.

How to delete records
  1. Press the “MEM” button for 3 seconds to delete records.
  2. The display will display “del all”, press “SET” to confirm or “Start/Stop” to cancel.
  3. If there is no record the monitor will display 3 dashes “- – -”
How many memories can I store?

A total of 60 records that show time, day and month can be stored in the memory. It will automatically delete the last record once the memory reached 60 data.